♨ Heating and energy

How much electricity does a heat pump use?

Relate heating demand, COP, operating hours and electricity price to estimate heat-pump running cost.

Reading time4–6 min
LevelIntermediate
TypePractical guide
Key ideaElectrical input is roughly heat output divided by COP, but real efficiency changes with conditions.
IN 30 SECONDS

What you need to know

  • COP links delivered heat to electrical input at a specific operating point.
  • Outdoor temperature and flow temperature can change performance.
  • Use seasonal data or measured consumption when you need a better annual estimate.

Use your own measurements

Use the linked BricoDato resource to check these inputs in your own situation. A heat pump moves heat; its thermal output is not the same as its electrical input.

Open heat-pump calculator
01 · LEARN

Start with heat demand

If the home needs 3 kW of heat and the heat pump operates at COP 3, electrical input is about 1 kW at that moment.

02 · LEARN

COP is not constant

Efficiency changes with outdoor temperature, indoor setpoint, defrost cycles and the temperature the system must deliver.

03 · LEARN

COP and SCOP are different

COP describes a particular test condition. SCOP is intended to represent seasonal performance and is more useful for broad annual comparisons.

04 · LEARN

Measure when possible

Smart-meter or dedicated energy data over several days can reveal cycling, weather effects and whether assumptions match reality.

PRACTICAL DECISION GUIDE

A heat-pump COP calculation with limits

A heat pump moves heat; its thermal output is not the same as its electrical input. COP is measured under specified conditions and can fall as outside temperature and operating requirements change.

Example to adapt

If a heat pump delivers an illustrative 6 kW of heat at COP 3, input is 6 ÷ 3 = 2 kW while that condition holds. For 5 equivalent full-load hours, the estimate is 10 kWh. At €0.20/kWh, the energy-only cost is €2.00. At COP 2, the same delivered heat would require 3 kW or 15 kWh over five hours.

Operating COPInput for 6 kW heatEnergy for 5 h
23.0 kW15 kWh
32.0 kW10 kWh
41.5 kW7.5 kWh

Checks before acting

  • Use actual heat demand rather than installed maximum output for long-term estimates.
  • Distinguish an instantaneous COP from seasonal SCOP figures and test conditions.
  • Consider defrost, auxiliary electric heating and hot-water settings separately.
  • Measure across representative colder and milder days if comparing real running costs.
Important: The calculation is not a prediction of a particular model or climate. Installation design, emitters and controls substantially affect performance.
QUALITY CHECK

Final check

Keep useful heating output and electrical energy separate. If a room needs 1,200 kWh of delivered heat during a period and a system averages a hypothetical seasonal efficiency of 3, electricity consumption is around 1,200 ÷ 3 = 400 kWh. The manufacturer’s ideal-condition COP is not that seasonal figure; outdoor temperatures, defrost and airflow can change the achieved result.

  • Use realistic heat demand.
  • Do not assume one COP all year.
  • Compare similar weather and setpoints.
  • Separate space heating from hot-water use when possible.
BricoDato idea: save the starting measurements and the final result so you can repeat the same check later instead of relying on memory.