Watts to kWh
kWh = (W ÷ 1,000) × hours × load factor. Multiply kWh by your electricity price to estimate energy cost.
Log initial and final relative humidity with a separate hygrometer. Replace example inputs with your own usage pattern.
300 W × 8 h/day × 60 % load factor × 30 days.
This is an energy-only estimate. Your bill can also include standing charges, taxes and other household consumption.
Use the label, manual or manufacturer data for your exact model whenever possible.
| Type or situation | Indicative reference |
|---|---|
| Small compressor unit | 180–300 W |
| Typical domestic unit | 250–450 W |
| Large / high-capacity unit | 400–700+ W |
Rated watts are only one part of the calculation.
kWh = (W ÷ 1,000) × hours × load factor. Multiply kWh by your electricity price to estimate energy cost.
Thermostats, compressors, inverter control and programmes can make real consumption lower or higher than a simple maximum-power estimate.
Return to the appliance library or use the general electricity calculator for any device.
A dehumidifier's rated wattage does not tell you how many hours the compressor will actually run. Once the room approaches the selected humidity target, many units cycle or reduce operation. The monthly result therefore depends on moisture load as much as on electrical power.
Compressor dehumidifiers generally remove water differently at lower room temperatures than under warmer test conditions. Open windows, drying laundry indoors, damp walls and repeated moisture entry can also keep the unit running for longer.
A dehumidifier can control indoor humidity, but it does not repair a leak or water ingress. If the moisture source is unclear, read how to control humidity at home before assuming continuous dehumidification is the solution.
Use the dehumidifier calculator for your own wattage and runtime, and check the current electricity price if you are in Spain.
Editorial review: 11 Oct 2026. Extraction ratings and real energy use depend on temperature and humidity conditions.
BRICODATO · PRACTICAL CHECK
Advertised litres per day depend on specified test conditions and may differ substantially in a cool room. Compare electricity use against the amount of moisture removed and the humidity target achieved. Running hours alone miss compressor cycling and room conditions.
The figures elsewhere on this page are illustrative assumptions, not a measured average for every model. Use the label, your actual cycle count and safely collected kWh readings.